Description
Across the Pacific Islands, India, Africa, the Caribbean, and South America, power outages are not an inconvenience — they are an expected reality. Cyclones, hurricanes, monsoons, flooding, and fragile grid infrastructure regularly interrupt electricity supply, often for days or even weeks.
For hospitals, resorts, data systems, commercial buildings, water infrastructure, and remote communities, reliable backup power is essential.
Apollo NZ | StormGuard Power delivers robust, fuel-efficient diesel generator solutions designed specifically for harsh climates, extreme weather events, and prolonged outages — ensuring continuity when the grid goes down.
Why Backup Power Is Critical in Storm-Prone Regions
Extreme weather events are increasing in frequency and intensity worldwide. In many regions, power infrastructure is already stretched, aging, or vulnerable to environmental damage.
Reliable backup power is critical for:
-
Emergency power during cyclones, hurricanes, and monsoons
-
Maintaining medical services and cold storage
-
Keeping resorts, hotels, and commercial facilities operational
-
Supporting water pumps, communications, and security systems
-
Powering remote or off-grid locations
When grid power fails, diesel generators remain one of the most dependable solutions, thanks to fuel availability, mechanical simplicity, and proven performance.
StormGuard Power 120kW – Built for Harsh Conditions
The StormGuard Power 120kW diesel generator is engineered for continuous, stable output in demanding environments, making it ideal for storm recovery and emergency backup power applications.
Key Electrical Specifications
-
Output Power: 120kW / 150kVA
-
Rated Voltage: 220 / 380V
-
Frequency: 50Hz
-
Phase: Three-phase, four-wire
-
Rated Current: 216A
-
Power Factor: 0.8 (Lagging)
-
Rated Speed: 1500 RPM
These specifications align with common electrical standards used across tropical and developing regions worldwide.
Diesel Engine – Designed for Reliability
At the core of StormGuard Power systems is a heavy-duty diesel engine designed for long operating hours and consistent performance during extended outages.
Engine Highlights
-
6-cylinder inline configuration
-
Turbocharged with direct injection
-
6.7L displacement
-
Water-cooled, four-stroke design
-
Fuel consumption ≤ 219 g/kW·h
-
24V electric start system
This configuration ensures strong torque, dependable starting, and stable operation during prolonged storm events.
Alternator & Electrical Stability
StormGuard Power generators are paired with commercial-grade alternators designed for stable voltage output and continuous-duty operation.
Alternator Features
-
Rated power: 120kW / 150kVA
-
IP21 protection rating
-
Three-phase output
-
Suitable for standby and extended runtime use
This ensures safe and reliable power for sensitive systems such as medical equipment, refrigeration, communications, and control infrastructure.
Silent or Open Type – Flexible Installation Options
To suit different environments and noise requirements, StormGuard Power generators are available in open-frame and silent enclosure configurations.
Open Type
-
Dimensions: 240 × 80 × 135 cm
-
Weight: 980 kg
Silent Type
-
Dimensions: 300 × 110 × 170 cm
-
Weight: 1480 kg
-
Sound-attenuated enclosure
The silent option is ideal for hospitals, resorts, residential zones, and emergency shelters, where noise control is critical during extended operation.
Regions We Supply
Apollo NZ | StormGuard Power systems are supplied globally for projects where power reliability is critical and environmental conditions are demanding.
Pacific Islands
-
Cyclone-prone island nations
-
Backup power for resorts, hospitals, and utilities
-
Remote and off-grid community power
Caribbean
-
Hurricane preparedness for hotels and commercial buildings
-
Emergency power for healthcare and cold-chain storage
-
Storm recovery and resilience projects
India
-
Monsoon-related power outages
-
Industrial and commercial standby power
-
Rural, semi-urban, and infrastructure support
Africa
-
Remote and off-grid power generation
-
Mining, construction, and agricultural operations
-
Backup power for hospitals, clinics, and utilities
South America
-
Flooding and storm-related outages
-
Backup power for commercial buildings and resorts
-
Power support for remote, rural, and industrial locations
Designed for Critical Power Scenarios
StormGuard Power systems are suited for professional installations where continuity is non-negotiable. They can be integrated with:
-
Automatic or manual transfer switches
-
Fuel storage and extended runtime systems
-
Hybrid solar-diesel power setups
-
Remote monitoring and control solutions
Power When the Grid Fails
When storms strike and power grids fail, preparedness is everything. A correctly sized generator ensures safety, continuity, and resilience — protecting people, assets, and operations.
Apollo NZ | StormGuard Power delivers dependable emergency power for regions where reliability cannot be left to chance.








